{"id":201,"date":"2015-11-05T11:32:17","date_gmt":"2015-11-05T11:32:17","guid":{"rendered":"http:\/\/www.shaktiheattech.com\/?page_id=201"},"modified":"2015-11-19T06:08:11","modified_gmt":"2015-11-19T06:08:11","slug":"gas-fired-thermic-fluid-heater","status":"publish","type":"page","link":"https:\/\/www.shaktiheattech.com\/index.php\/gas-fired-thermic-fluid-heater\/","title":{"rendered":"Gas Fired Thermic Fluid Heater"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-342\" src=\"https:\/\/www.shaktiheattech.com\/wp-content\/uploads\/2015\/11\/gas-fired-thermic-heater.jpg\" alt=\"gas fired thermic heater\" width=\"940\" height=\"375\" srcset=\"https:\/\/www.shaktiheattech.com\/wp-content\/uploads\/2015\/11\/gas-fired-thermic-heater.jpg 940w, https:\/\/www.shaktiheattech.com\/wp-content\/uploads\/2015\/11\/gas-fired-thermic-heater-300x120.jpg 300w\" sizes=\"auto, (max-width: 940px) 100vw, 940px\" \/><\/p>\n<p>Shree Shakti Industries offers thermic fluid heaters fired by a wide range of fuels.<\/p>\n<p>Our heaters are available in both solid fuel firing as well as oil\/gas firing version for flexibility of economically available fuels.<\/p>\n<p>Flowtherm is a fully automatic, 3 pass, oil\/gas fired packaged Thermic Fluid Heater capable of supplying process heat up to 300\u00b0 C at near atmospheric pressure. As the same oil is re-circulated again between source and sinks.<\/p>\n<p>Thermic Fluid Heating system is adaptable to precise temperature control.<\/p>\n<h3>Features:<\/h3>\n<ul>\n<li>Range From 50,000 kcal\/hr to 20,00,000 kcal\/hr<\/li>\n<li>88% \u00b1 2% Efficiency (Based on NCV)<\/li>\n<li>Maximum Supply Temperature-320 \u00b0 C<\/li>\n<li>Easy And Economical Operation<\/li>\n<li>Fuel: FO\/ LDO\/ HSD\/ Natural Gas\/<\/li>\n<li>Fully Automatic<\/li>\n<li>Outside Purview OSf IBR<\/li>\n<\/ul>\n<h3>Technical Specification:<\/h3>\n\n<table id=\"tablepress-4\" class=\"tablepress tablepress-id-4\">\n<thead>\n<tr class=\"row-1 odd\">\n\t<th class=\"column-1\"><\/th><th class=\"column-2\">Unit<\/th><th class=\"column-3\">SS-100<\/th><th class=\"column-4\">SS-200<\/th><th class=\"column-5\">SS-400<\/th><th class=\"column-6\">SS-600<\/th><th class=\"column-7\">SS-1000<\/th><th class=\"column-8\">SS-1500<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\">Heat Output<\/td><td class=\"column-2\">Million K cal\/hr<\/td><td class=\"column-3\">0.1<\/td><td class=\"column-4\">0.2<\/td><td class=\"column-5\">0.4<\/td><td class=\"column-6\">0.6<\/td><td class=\"column-7\">1.01<\/td><td class=\"column-8\">1.5<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\">Burner Turn Down<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td><td class=\"column-5\">1:3<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td><td class=\"column-8\"><\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td class=\"column-1\">Thermic Fluid Flow Rate<\/td><td class=\"column-2\">m<sup>3<\/sup>\/hr<\/td><td class=\"column-3\">9<\/td><td class=\"column-4\">15<\/td><td class=\"column-5\">26<\/td><td class=\"column-6\">42<\/td><td class=\"column-7\">75<\/td><td class=\"column-8\">110<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n\t<td class=\"column-1\">Thermic Fluid Outlet Temperature<\/td><td class=\"column-2\">\u2103<\/td><td class=\"column-3\">300<\/td><td class=\"column-4\">300<\/td><td class=\"column-5\">300<\/td><td class=\"column-6\">300<\/td><td class=\"column-7\">300<\/td><td class=\"column-8\"><\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n\t<td class=\"column-1\">Thermic Fluid Temp. Rise<\/td><td class=\"column-2\">\u2103<\/td><td class=\"column-3\">30<\/td><td class=\"column-4\">30<\/td><td class=\"column-5\">30<\/td><td class=\"column-6\">30<\/td><td class=\"column-7\">32<\/td><td class=\"column-8\">32<\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n\t<td class=\"column-1\">Thermal Efficiency<\/td><td class=\"column-2\">%<\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td><td class=\"column-5\">87+2%<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td><td class=\"column-8\"><\/td>\n<\/tr>\n<tr class=\"row-8 even\">\n\t<td colspan=\"3\" class=\"column-1\"><\/td><td colspan=\"5\" class=\"column-4\"><h3>Fuel Consumption on NCV basic<\/h3><\/td>\n<\/tr>\n<tr class=\"row-9 odd\">\n\t<td class=\"column-1\">Light Diesel Oil (10500 Kcal\/Kg)<\/td><td class=\"column-2\">Kg\/hr<\/td><td class=\"column-3\">10.90<\/td><td class=\"column-4\">21.89<\/td><td class=\"column-5\">43.78<\/td><td class=\"column-6\">65.68<\/td><td class=\"column-7\">109.46<\/td><td class=\"column-8\">164.20<\/td>\n<\/tr>\n<tr class=\"row-10 even\">\n\t<td class=\"column-1\">Natural Gas (8400 Kcal\/nm<sup>2<\/sup>)<\/td><td class=\"column-2\">nm<sup>2<\/sup>\/hr<\/td><td class=\"column-3\">13.68<\/td><td class=\"column-4\">27.36<\/td><td class=\"column-5\">54.72<\/td><td class=\"column-6\">82.10<\/td><td class=\"column-7\">136.83<\/td><td class=\"column-8\">205.25<\/td>\n<\/tr>\n<tr class=\"row-11 odd\">\n\t<td colspan=\"3\" class=\"column-1\"><\/td><td colspan=\"4\" class=\"column-4\"><h3>Electrical Coonected Load<\/h3><\/td><td class=\"column-8\"><\/td>\n<\/tr>\n<tr class=\"row-12 even\">\n\t<td class=\"column-1\">Thermic Fluid Pump<\/td><td class=\"column-2\">Kw<\/td><td class=\"column-3\">3.70<\/td><td class=\"column-4\">5.50<\/td><td class=\"column-5\">7.50<\/td><td class=\"column-6\">9.30<\/td><td class=\"column-7\">11.00<\/td><td class=\"column-8\">15.00<\/td>\n<\/tr>\n<tr class=\"row-13 odd\">\n\t<td class=\"column-1\">Bumer Blower<\/td><td class=\"column-2\">Kw<\/td><td class=\"column-3\">0.76<\/td><td class=\"column-4\">0.76<\/td><td class=\"column-5\">1.50<\/td><td class=\"column-6\">2.20<\/td><td class=\"column-7\">5.66<\/td><td class=\"column-8\">7.50<\/td>\n<\/tr>\n<tr class=\"row-14 even\">\n\t<td class=\"column-1\">Electric Heater<\/td><td class=\"column-2\">Kw<\/td><td class=\"column-3\">2.00<\/td><td class=\"column-4\">3.00<\/td><td class=\"column-5\">4.00<\/td><td class=\"column-6\">6.00<\/td><td class=\"column-7\">9.00<\/td><td class=\"column-8\">12.00<\/td>\n<\/tr>\n<tr class=\"row-15 odd\">\n\t<td class=\"column-1\">Fuel Pump<\/td><td class=\"column-2\">Kw<\/td><td class=\"column-3\">0.76<\/td><td class=\"column-4\">0.76<\/td><td class=\"column-5\">0.76<\/td><td class=\"column-6\">0.76<\/td><td class=\"column-7\">1.50<\/td><td class=\"column-8\">1.50<\/td>\n<\/tr>\n<tr class=\"row-16 even\">\n\t<td class=\"column-1\">Total Electric Load<\/td><td class=\"column-2\">Kw<\/td><td class=\"column-3\">7.20<\/td><td class=\"column-4\">10.02<\/td><td class=\"column-5\">13.76<\/td><td class=\"column-6\">18.26<\/td><td class=\"column-7\">27.36<\/td><td class=\"column-8\">36.00<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-4 from cache -->\n","protected":false},"excerpt":{"rendered":"<p>Shree Shakti Industries offers thermic fluid heaters fired by a wide range of fuels. Our heaters are available in both solid fuel firing as well as oil\/gas firing version for flexibility of<a class=\"moretag\" href=\"https:\/\/www.shaktiheattech.com\/index.php\/gas-fired-thermic-fluid-heater\/\">Read More&#8230;<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-201","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.shaktiheattech.com\/index.php\/wp-json\/wp\/v2\/pages\/201","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.shaktiheattech.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.shaktiheattech.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.shaktiheattech.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.shaktiheattech.com\/index.php\/wp-json\/wp\/v2\/comments?post=201"}],"version-history":[{"count":6,"href":"https:\/\/www.shaktiheattech.com\/index.php\/wp-json\/wp\/v2\/pages\/201\/revisions"}],"predecessor-version":[{"id":343,"href":"https:\/\/www.shaktiheattech.com\/index.php\/wp-json\/wp\/v2\/pages\/201\/revisions\/343"}],"wp:attachment":[{"href":"https:\/\/www.shaktiheattech.com\/index.php\/wp-json\/wp\/v2\/media?parent=201"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}